Nonsystem reasons for delay in door-to-balloon time and associated in-hospital mortality: a report from the National Cardiovascular Data Registry

J Am Coll Cardiol. 2013 Apr 23;61(16):1688-95. doi: 10.1016/j.jacc.2012.11.073. Epub 2013 Mar 27.

Abstract

Objectives: The goal of this study was to characterize nonsystem reasons for delay in door-to-balloon time (D2BT) and the impact on in-hospital mortality.

Background: Studies have evaluated predictors of delay in D2BT, highlighting system-related issues and patient demographic characteristics. Limited data exist, however, for nonsystem reasons for delay in D2BT.

Methods: We analyzed nonsystem reasons for delay in D2BT among 82,678 ST-segment elevation myocardial infarction patients who underwent primary percutaneous coronary intervention within 24 h of symptom onset in the CathPCI Registry from January 1, 2009, to June 30, 2011.

Results: Nonsystem delays occurred in 14.7% of patients (n = 12,146). Patients with nonsystem delays were more likely to be older, female, African American, and have greater comorbidities. The in-hospital mortality for patients treated without delay was 2.5% versus 15.1% for those with delay (p < 0.01). Nonsystem delay reasons included delays in providing consent (4.4%), difficult vascular access (8.4%), difficulty crossing the lesion (18.8%), "other" (31%), and cardiac arrest/intubation (37.4%). Cardiac arrest/intubation delays had the highest in-hospital mortality (29.9%) despite the shortest time delay (median D2BT: 84 min; 25th to 75th percentile: 64 to 108 min); delays in providing consent had a relatively lower in-hospital mortality rate (9.4%) despite the longest time delay (median D2BT: 100 min; 25th to 75th percentile: 80 to 131 min). Mortality for delays due to difficult vascular access, difficulty crossing a lesion, and other was also higher (8.0%, 5.6%, and 5.9%, respectively) compared with nondelayed patients (p < 0.0001). After adjustment for baseline characteristics, in-hospital mortality remained higher for patients with nonsystem delays.

Conclusions: Nonsystem reasons for delay in D2BT in ST-segment elevation myocardial infarction patients presenting for primary percutaneous coronary intervention are common and associated with high in-hospital mortality.

MeSH terms

  • Aged
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / mortality*
  • Coronary Angiography
  • Female
  • Hospital Mortality*
  • Humans
  • Male
  • Middle Aged
  • Myocardial Infarction / mortality
  • Myocardial Infarction / therapy*
  • Registries
  • Retrospective Studies
  • Time Factors