Percutaneous implantation of the CoreValve self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain

Rev Esp Cardiol. 2010 Feb;63(2):141-8. doi: 10.1016/s1885-5857(10)70031-1.
[Article in English, Spanish]

Abstract

Introduction and objectives: The aim of the study was to describe early experience and medium-term follow-up with the CoreValve self-expanding aortic prosthesis at three Spanish hospitals.

Methods: The study included patients with severe symptomatic aortic stenosis. Other inclusion criteria were: aortic valve area <1 cm(2) (<0.6 cm(2)/m(2)); aortic valve annulus diameter in the range 20-27 mm; diameter of the ascending aorta at the level of the sinotubular junction < or = 40 mm (small prosthesis) or < or = 43 mm (large prosthesis), and femoral artery diameter >6 mm.

Results: The study included 108 patients with a mean age of 78.6 + or - 6.7 years, a mean aortic valve area of 0.63 + or - 0.2 cm(2) and a mean logistic EuroSCORE of 16% + or - 13.9% (range, 2.27%-86.4%). After valve implantation, the maximum echocardiographic transaortic valve gradient decreased from 83.8 + or - 23 to 12.6 + or - 6 mmHg. No patient presented with greater than grade-2 residual aortic regurgitation on angiography. The procedural success rate was 98.1%. No patient died during the procedure. Definitive pacemaker implantation was carried out for atrioventricular block in 38 patients (35.2%). At 30 days, all-cause mortality and the rate of the combined endpoint of death, stroke, myocardial infarction or referral for surgery were 7.4% and 8.3%, respectively. The estimated 1-year survival rate calculated using the Kaplan-Meier method was 82.3% (for a median follow-up period of 7.6 months).

Conclusions: Our early experience indicates that percutaneous aortic valve replacement is a safe and practical therapeutic option for patients with severe aortic stenosis who are at a high surgical risk.

Publication types

  • Clinical Trial
  • Multicenter Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery*
  • Aortic Valve Insufficiency / diagnostic imaging
  • Aortic Valve Insufficiency / surgery
  • Cardiac Catheterization / methods*
  • Female
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Perioperative Care
  • Platelet Aggregation Inhibitors / therapeutic use
  • Prospective Studies
  • Spain
  • Survival Analysis
  • Treatment Outcome
  • Ultrasonography

Substances

  • Platelet Aggregation Inhibitors