Efficacy of a home blood pressure monitoring programme on therapeutic compliance in hypertension: the EAPACUM-HTA study

J Hypertens. 2006 Jan;24(1):169-75. doi: 10.1097/01.hjh.0000198023.53859.a2.

Abstract

Objective: To evaluate the efficacy of a programme of home blood pressure measurement (HBPM) on therapeutic compliance in mild-to-moderate hypertension.

Design: A prospective controlled multicentre clinical trial.

Setting: Forty primary care centres in Spain, with a duration of 6 months.

Patients: A total of 250 patients with newly diagnosed or uncontrolled hypertension were included.

Interventions: The patients were randomly selected and distributed in two groups: (1) the control group (CG) who received standard health intervention; (2) the intervention group (IG): the patients in this group received an OMRON in their homes for a programme of HBPM.

Main outcome measure: Four visits were scheduled, for the measurement of blood pressure (BP). They were provided with an electronic monitor for measuring compliance (monitoring events medication system; MEMS). Therapeutic compliance was defined as a drug consumption of 80-110%. A number of variables were calculated using the MEMS. The mean BP were calculated and the percentage of controlled patients.

Results: A total of 200 patients completed the study (100 in each group). Compliance was observed in 74 and 92%, respectively, in the CG and IG [95% confidence interval (CI) 63.9-84.1 and 86.7-97.3; P = 0.0001], the mean percentage compliances were 87.6 and 93.5% (95% CI 81.2-94 and 80.7-98.3; P = 0.0001), the percentages of correct days were 83.6 and 89.4%, the percentages of subjects who took the medication at the prescribed time were 79.89 and 88.06%, and the levels of therapeutic cover were 86.7 and 93.1%. The number needed to treat to avoid one case of non-compliance was 5.6 patients. The differences in the mean decreases in BP were significant for diastolic BP, with a greater decrease observed in the IG.

Conclusions: An HBPM programme using electronic monitors is effective in improving compliance in arterial hypertension, measured using the MEMS.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Antihypertensive Agents / pharmacology
  • Antihypertensive Agents / therapeutic use*
  • Blood Pressure / drug effects
  • Blood Pressure / physiology*
  • Blood Pressure Monitoring, Ambulatory*
  • Blood Pressure Monitors
  • Data Interpretation, Statistical
  • Female
  • Humans
  • Hypertension / drug therapy*
  • Hypertension / physiopathology
  • Male
  • Middle Aged
  • Patient Compliance*
  • Prospective Studies

Substances

  • Antihypertensive Agents