Tricuspid valve repair: durability and risk factors for failure

J Thorac Cardiovasc Surg. 2004 Mar;127(3):674-85. doi: 10.1016/j.jtcvs.2003.11.019.

Abstract

Objectives: To compare durability of tricuspid valve annuloplasty techniques, identify risk factors for repair failure, and characterize survival, reoperation, and functional class of surviving patients.

Methods: From 1990 to 1999, 790 patients (mean age 65 +/- 12 years, 51% New York Heart Association functional class III or IV, and mean right ventricular systolic pressure 56 +/- 18 mm Hg) underwent tricuspid valve annuloplasty for functional regurgitation using 4 techniques: Carpentier-Edwards semi-rigid ring, Cosgrove-Edwards flexible band, De Vega procedure, and customized semicircular Peri-Guard annuloplasty. Of these patients, 89% had concomitant mitral valve surgery. A total of 2245 follow-up transthoracic echocardiograms were retrieved. Tricuspid regurgitation was analyzed, and risk factors for worsening regurgitation were identified, by multivariable ordinal longitudinal methods.

Results: Tricuspid regurgitation 1 week after annuloplasty was 3+ or 4+ in 14% of patients. Regurgitation severity was stable across time with the Carpentier-Edwards ring (P =.7), increased slowly with the Cosgrove-Edwards band (P =.05), and rose more rapidly with the De Vega (P =.002) and Peri-Guard (P =.0009) procedures. Risk factors for worsening regurgitation included higher preoperative regurgitation grade, poor left ventricular function, permanent pacemaker, and repair type other than ring annuloplasty. Right ventricular systolic pressure, ring size, preoperative New York Heart Association functional class, and concomitant surgery were not risk factors. Tricuspid reoperation was rare (3% at 8 years), and hospital mortality after reoperation was 37%.

Conclusions: Tricuspid valve annuloplasty did not consistently eliminate functional regurgitation, and across time regurgitation increased importantly after Peri-Guard and De Vega annuloplasties. Therefore, these repair techniques should be abandoned, and transtricuspid pacing leads should be replaced with epicardial leads.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Disease Progression
  • Female
  • Humans
  • Male
  • Middle Aged
  • Reoperation
  • Risk Factors
  • Treatment Failure
  • Tricuspid Valve / surgery*
  • Tricuspid Valve Insufficiency / physiopathology
  • Tricuspid Valve Insufficiency / surgery*
  • Ventricular Function, Right
  • Ventricular Pressure