Echocardiographic evaluation of left ventricular function during coronary artery angioplasty

https://doi.org/10.1016/0002-9149(86)90944-6Get rights and content

Abstract

Balloon occlusion of a stenotic coronary artery during percutaneous coronary artery angioplasty provides a unique opportunity to study the effect of acute myocardial ischemia on left ventricular (LV) function. Simultaneous M-mode and 2-dimensional (2-D) echocardiograms and a 6-lead electrocardiogram were recorded during 20 episodes of coronary artery occlusion and release in 12 patients. No patient had previous myocardial infarction and all had normal LV function by angiography. All patients had isolated single coronary artery disease, with left anterior descending stenosis in 8 and right coronary stenosis in 4. In 18 of 20 episodes (90%), M-mode echocardiography during balloon occlusion revealed a significant (p <0.001) decrease in LV systolic, diastolic and percent systolic wall thickness; systolic excursion; systolic and diastolic endocardial velocities; and fractional shortening. These changes were observed in the area of the ventricular septum in patients with left anterior descending occlusion and posteroinferior wall in those with right coronary artery occlusion. Two-dimensional echocardiography revealed varying degrees of hypokinesia, akinesia and dyskinesia during balloon occlusion in 18 instances. The echocardiogaphy changes were observed within 15 to 20 seconds of balloon occlusion and resolved 10 to 20 seconds after balloon deflation. All patients who had echocardogaphy changes during balloon occlusion also had concomitant electrocardiographic (ECG) ST-segment elevation, whereas 2 patients with normal LV function had no ECG changes. Both of these patients had profuse collateral blood supply to the stenotic coronary artery. The echocardiographic and ECG abnormalities increased proportionately to the length of balloon occlusion. This study confirms previous animal and recent human studies of transient LV dysfunction during coronary occlusion. Echocardiography during balloon angioplasty provides a unique model to study the effects of myocardial ischemia in humans.

Cited by (63)

  • Identification of acutely ischemic myocardium using ultrasonic strain measurements: A clinical study in patients undergoing coronary angioplasty

    2003, Journal of the American College of Cardiology
    Citation Excerpt :

    The potential differences in the response to an acute ischemic insult of each of these pathophysiologic entities require additional investigation and were not the aim of our study. The attempt to quantify the ischemia-induced changes in regional myocardial function using noninvasive imaging is not new (5–10,29). In an experimental model of acute coronary occlusion, Kerber et al. (30)have shown the potential value of gray-scale M-mode for the assessment of segmental asynergy.

  • Acute changes in systolic and diastolic events during clinical coronary angioplasty: A comparison of regional velocity, strain rate, and strain measurement

    2002, Journal of the American Society of Echocardiography
    Citation Excerpt :

    Controls were scanned in the lateral decubitus position, whereas patients were examined in a supine position. B-mode CDMI myocardial velocity data were acquired at a frame rate of 147 fps4 by using an imaging sector angle of 45 degrees. Pulse repetition frequency was adjusted to avoid aliasing.

  • Basic and clinical aspects of myocardial stunning

    1998, Progress in Cardiovascular Diseases
View all citing articles on Scopus
View full text