Table 2

Overview of pooled AF detection rates

SubgroupNo of studiesNo of patientsPooled AF detection rate (95% CI)Heterogeneity
CasesTotalI2 (%)P value
ILR monitoring23701287024.5% (20.0% to 29.6%)81.4<0.0001
Duration of monitoring
 1 month3316474.9% (3.0% to 7.9%)0.00.65
 3 months16886.8% (3.0% to 14.4%)
 6 months57149815.7% (7.7% to 29.3%)81.3<0.0001
 12 months12267147518.0% (14.0% to 22.7%)64.9<0.0001
 18 months35629619.0% (13.7% to 25.8%)0.00.69
 24 months7285123822.3% (18.9% to 26.1%)36.00.15
 30 months38121139.4% (7.8% to 83.3%)90.2<0.0001
 36 months31183170.3% (0.1% to 0.7%)66.20.052
AF cut-off
 30 s818186720.8% (17.4% to 24.6%)23.40.24
 60 s1386558.5% (46.2% to 69.7%)
 120 s13457188424.0% (18.3% to 30.7%)79.1<0.0001
 300 s1255446.3% (33.6% to 59.5%)
Time of device implant from stroke/TIA
 <7 days210540836.6% (0.0% to 100%)97.3<0.0001
 <28 days410941124.5% (11.4% to 45%)85.4<0.0001
 >28 days11281121922.5% (15.9% to 31%)79.4<0.0001
 MCOT monitoring19262209411.2% (8.2% to 15.1%)72.3<0.0001
Duration of monitoring
 <2 days14725.6% (2.1% to 13.9%)
 <14 days7586409.4% (5.7% to 15.2%)54.40.040
 <28 days14228162112.8% (8.9% to 17.9%)70.6<0.0001
AF cut-off
 30 s19218183410.5% (7.4% to 14.6%)71.6<0.0001
 60 s11211410.5% (6.1% to 17.6%)
 120 s13214621.9% (16.0% to 29.4%)
Time of device use from stroke/TIA
 <7 days46841914.9% (6.5% to 30.8%)73.40.010
 <28 days4223437.0% (2.4% to 18.3%)37.50.19
 >28 days56554010.9% (6.2% to 18.5%)42.90.14
Device type
 Wireless recorder911699611.2% (8.1% to 15.3%)43.20.079
 Patch3192219.1% (3.3% to 22.6%)6.40.34
 Chest belt511167015.5% (7.0% to 30.9%)81.90.0002
 Handheld device3312728.6% (0.3% to 74.5%)82.40.0034
 Inpatient monitoring7175148412.6% (7.3% to 21.0%)89.2<0.0001
  • AF, atrial fibrillation; ILR, implantable loop recorder; MCOT, mobile cardiac outpatient telemetry; TIA, transient ischaemic attack.