Table 1

Baseline and procedural characteristics

All patients n=30
Age (years)81±5
Female sex14 (47%)
Hypertension22 (73%)
Diabetes7 (23%)
Coronary artery disease16 (53%)
Prior stroke3 (10%)
STS PROM, %2.9±2.6
Mean transvalvular gradient, mm Hg49±17
Aortic valve area, cm²0.8±0.2
LVEF, %62±9
Annulus size (mm, IQR)
 Short diameter22 (21–23)
 Long diameter26 (25–28)
Device landing zone calcification
 None13 (43%)
 Mild9 (30%)
 Moderate8 (27%)
 Severe0 (0%)
Leaflet calcification
 None0 (0%)
 Mild6 (20%)
 Moderate15 (50%)
 Severe9 (30%)
Valve size
 Small7 (23%)
 Medium12 (40%)
 Large11 (37%)
Degree of valve oversizing (%)6.0 (2.0–9.0)
Cover index (%)5.3 (2.0–8.0)
Predilatation28 (98%)
Postdilatation8 (27%)
Implantation depth (mm, IQR)4 (3–5)
Conscious sedation30 (100%)
Procedure duration min, IQR47 (35–57)
Conversion to surgery0 (0%)
  • Data are displayed as n (%) or mean±SD or median (IQR).

  • Cover index defined as 100×((prosthesis diameter–CT annulus diameter)/prosthesis diameter).

  • LVEF, left ventricular ejection fraction; STS PROM, Society of Thoracic Surgeons Predicted Risk of Mortality.