Table 3

Comparison of the ambient dose equivalent (nSV) for conventional and upside-down positioning in different models averaged over all three angulations

ModelPositionPOP valueAssistantP valueNurseP valueAnaesthetistP value
AdultConventional2569±807<0.0161±54<0.0115±90.418±60.26
Upside-down135±23134±6014±710±6
PaediatricConventional351±104<0.0124±18<0.011±30.712±51
Upside-down121±5657±302±42±5
SphericalConventional3907±883<0.01100±70<0.0121±70.8512±50.17
Upside-down126±13253±16922±813±4