B. Interrogated vessel featuresTotal (n=504)
Lesion location
 LAD348 (69.0%)
 LCx56 (11.1%)
 RCA100 (19.8%)
Three-dimensional QCA
RD (mm)2.8 (2.5–3.1)
 MLD (mm)1.4 (1.1–1.7)
 Diameter stenosis (%)49.6±12.0
 Area stenosis (%)66.7 (55.6–75.3)
 Lesion length (mm)18.4 (13.1–24.0)
fQFR0.78 (0.72–0.87)
cQFR0.79 (0.74–0.88)
Invasive physiological indices
 FFR0.81 (0.74–0.87)
 CFR2.7 (1.8–3.7)
 IMR20.1 (13.4–30.0)
 Corrected IMR19.0 (12.6–27.5)
 Baseline, Tmn (s)0.84 (0.59–1.18)
 Hyperaemic, Tmn (s)0.30 (0.21–0.46)
Duke jeopardy score2 (2–6)
  • Variables are expressed as n (%), median (IQR) or mean±SD. IMR correction was performed using Yong’s formula.

  • CFR, coronary flow reserve; cQFR, contrast-flow quantitative flow ratio; FFR, fractional flow reserve; fQFR, fixed-flow quantitative flow ratio; IMR, index of microcirculatory resistance; LAD, left anterior descending artery; LCx, left circumflex artery; MLD, minimal lumen diameter; QCA, quantitative coronary angiography; RCA, right coronary artery; RD, reference diameter; Tmn, mean transit time.