TableĀ 3

Variables associated with delirium and mortality after transcatheter aortic valve implantation (TAVI), multivariate logistic regression analysis and Cox proportional hazards regression analysis

Deliriump Value
OR95% CIR2=0.359
Age1.040.93 to 1.170.47
Pulmonary hypertension0.310.10 to 1.040.06
Mini Mental State Examination0.730.53 to 0.990.04*
Instrumental Activities of Daily Living1.300.81 to 2.100.28
Timed up and Go1.150.99 to 1.340.08
Mortality HR 95% CIp Value
R2=0.271
Age0.940.84 to 1.060.32
Frailty Index1.821.04 to 3.180.04*
EuroSCORE II1.131.05 to 1.220.002*
Complications4.310.89 to 20.950.07
  • *Significance level p<0.05.

  • EuroSCORE, European System for Cardiac Operative Risk Evaluation.