Article Text

Download PDFPDF

Original research
Incremental role of CT coronary angiography in the assessment of left ventricular diastolic function
  1. Aleksandra Lange,
  2. Harry Huntress,
  3. Jesse Steindl and
  4. Przemyslaw Palka
  1. Queensland Cardiovascular Group, Wesley Medical Research Limited, St Andrew's War Memorial Hospital, Brisbane, Queensland, Australia
  1. Correspondence to Dr Aleksandra Lange; aleksandral{at}qcg.com.au

Abstract

Objective To determine whether Computed Tomography (CT) coronary angiography (CTCA) has clinical value for the assessment of left ventricular (LV) diastolic dysfunction (DD) beyond traditional information on coronary artery anatomy.

Method In this retrospective study, a consecutive group of 72 patients (mean age 59±13 years)—who met the eligibility criteria of sinus rhythm, no significant valvular abnormalities, and who had transthoracic echocardiogram (TTE)—were analysed. The CTCA was prospectively triggered during diastole. Outcomes of interest were CTCA derived LV and left atrial (LA) volumes, diastolic expansion (DE) index: LV volume÷LA volume and DE fraction (DEF): [(LV volume–LA volume)÷LV volume]×100. TTE-LA volume was measured as maximum, minimum and pre-A. Studied patients were divided according to the current classification of LVDD as a reference standard. A small subgroup of nine patients underwent further invasive cardiac catheterisation.

Results CTCA-LV and LA volumes were larger compared with TTE, 37%±20% and 11%±21%, respectively. CTCA-LA volume correlated well with all TTE-LA volumes (maximum: R2=0.58; pre-A wave: R2=0.39; minimum: R2=0.26; p<0.0001) with the smallest differences in maximum LA volume (9±32 mL; mean±2 SD). The DE and DEF correlated with both LA function and LVDD. DE >1.65 and DE <1.40 have good specificity (85% and 88%, respectively), and positive predictive value to differentiate LVDD. DE and DEF were dependent on the patients’ age but independent of other variables.

Conclusions CTCA derived diastasis volume indices can provide additional quantifiable information on LVDD.

  • CT angiography
  • echocardiography
  • heart failure
  • diastolic
http://creativecommons.org/licenses/by-nc/4.0/

This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Key questions

What is already known about this subject?

  • CT coronary angiography (CA) is considered as the first choice test in patients with chest pain and intermediate pretest probability. It has the potential to reliably exclude obstructive coronary artery disease.

What does this study add?

  • This study proposes a new index that may assist in detection of left ventricular diastolic dysfunction and thus, refine risk stratification in patients undergoing CTCA.

How might this impact on clinical practice?

  • This new index obtained from routine CTCA may add to the growing list of noncoronary applications of cardiac CT. Such an incremental prognostic value index may potentially translate into more relevant information and as a result improve the management and the prognosis.

Over the last two decades a great deal of progress has been achieved in refining imaging techniques in order to improve the diagnosis of coronary artery disease (CAD). CT coronary angiography (CA) is considered as the first choice test in patients with suspected CAD and intermediate pretest probability.1–7 It has the potential to reliably exclude obstructive CAD8 9 while halving the events of coronary heart disease after 5 years of follow-up and improving the diagnostic yield of CA.5

Volumetric analysis of either atrial7–11 or ventricular size and function12–14 using retrospective gating CT acquisition, were reported as accurate. Since the data of prospective ECG CT triggering in the measurement of left ventricular (LV) volume is acquired at a predefined phase of the cardiac cycle, there is little information on the use of this protocol as the results need to be modified in order to estimate standard measurement of end-diastolic values.14

The availability of information on the potential role of cardiac CT in the assessment of LV diastolic dysfunction (DD)15–17 is low. Reports to date used retrospective ECG gating for the acquisition of a full cardiac cycle data which inherently has higher radiation doses. These reports provide novel insights by assessing LVDD at the same time as assessing CAD, further evolving cardiac CT towards a more comprehensive technique in cardiovascular function assessment. The use of prospective ECG triggering reduces the radiation dose but also limits data acquisition to a particular phase of a cardiac cycle—either systolic or diastolic. It has been shown that in patients without tachyarrhythmia, prospectively triggered CTCA provides image quality and diagnostic accuracy comparable with retrospectively gated cardiac CT.18 19

The aim was to evaluate whether CTCA derived information acquired from routine prospective ECG triggered image acquisition is useful in distinguishing patients with, and without, LVDD as supported by the reference of transthoracic echocardiogram (TTE), and a small group of patients in whom catheterisation data were available.

Methods

Patient and public involvement

The patients studied were referred for a CTCA to the Queensland Cardiovascular Group at St. Andrew’s War Memorial Hospital (AL and PP), Brisbane, Australia—an expert tertiary referral centre for CAD patients—from June 2019 until November 2019. All patients have given informed written consent for their clinical data to be used in the study. Patients were not involved in either the design or the conduct of the study.

Patient selection

Patients with chest pain presentation and low-moderate probability of CAD were chosen from our clinical referral cohort if they met the following selection criteria1: sinus rhythm,2 absence of valvopathy ≥2/4,3 availability of CTCA and TTE of diagnostic image quality (figure 1, table 1). Patients with LV ejection fraction (LVEF) <50%, pacing, unstable angina or history of obstructive CAD, coronary revascularisation, myocardial infarction or coronary artery bypass surgery were excluded. We further excluded patients with incomplete TTE data. As a result, 23 patients (24%) were excluded from the original cohort of 95 patients. Seventy-two patients were included for further analysis. The female subgroup consisted of 38 patients (53%). The mean age of study group was 59±13 years. The average heart rate was 56±6 beats/min for CTCA and 70±11 for TTE.

Figure 1

Patient selection criteria. CTCA, CT coronary angiogram.

Table 1

Patient demographics

A group of 9 out of 72 patients underwent invasive CA. The results confirmed that 4/9 patients had obstructive CA. Therefore, it is fair to assume that they must have had elevated LV end-diastolic filling pressure. LV end-diastolic pressure was measured as elevated in the remaining five out of nine patients. Therefore, it is assumed that all nine patients had elevated LV filling pressures.

Time difference between CTCA and TTE was 16±24 days (mean±SD). The data was collected retrospectively.

We followed the STARD (Standards for Reporting of Diagnostic Accuracy Studies) guidance for conducting and reporting quality.

Scanning method

CTCA was acquired in a standard manner using 256iCT Philips scanner (Philips North America Corporation, Andover, Massachusetts).

An injection of iodinated contrast media (Omnipaque 350) was used to opacify the coronary arteries and subsequently the LA and the LV. A contrast bolus of 75–100 mL was injected at a rate of 5–6 mL/s according to standard protocol. Scanning was initialised when the region of interest reached above 200 HU. The scan was acquired during a single breath-hold. The Z-axis scan range had a border of the pulmonary artery bifurcation superiorly and the inferior border of the heart inferiorly.

The iCT has 270 ms gantry rotation time and a temporal resolution of 135 ms. Scan parameters were 128×0.625 mm collimation. Philip’s Iterative Reconstruction algorithm, Iterative Model Reconstruction, was applied to the datasets allowing conservation of dose. kV and effective mAs were manually selected. Patients with a body mass index (BMI) <30 were scanned with a 100 kV technique while those with BMI >30 were scanned with a 120 kV technique. Only patients scanned in diastasis between 75% and 81% of the R-R interval were chosen for the analysis with the standard acquisition occurring at 78% (figure 2).

Figure 2

Schematic diagram illustrating CT coronary angiogram data capture during a cardiac cycle. LA, left atrium; LV, left ventricle.

Patients with heart rates ≥65/min were given 50 mg of atenolol in a single dose, or 100 mg in two divided doses orally (unless contraindicated). All patients receive sublingual nitroglycerin before CTCA.

LA volume was measured with exclusion for the LA appendage by two expert readers who were blinded to TTE results. LV volume was measured using an automated algorithm.

CTCA diastolic function assessment–the diastolic expansion (DE) was measured as ratio between LV and LA volume. The DE fraction (DEF) was measured as: [(LV volume–LA volume)÷LV volume]×100.

TTE was acquired using commercially available equipment Phillips EPIQ CVx (Philips North America Corporation) or Siemens SC200 (Siemens Medical Solutions, Mountain View, California, USA). Standard clinical imaging protocol was applied in each patient. The protocol consisted of M-mode, two-dimensional and Doppler analysis. Apical views were optimised to avoid foreshortening of the LA. The LA area was planimetered from the 4-chamber and the 2-chamber view, excluding the LA appendage and the pulmonary veins. Subsequent LA volumes were calculated using the biplane method.20 LA volume was measured in three phases of the cardiac cycle: maximum (at LV end-systole), minimum (at LV end-diastole) and pre-A (immediately before atrial contraction pre-P wave in ECG) (figure 2). Each measurement was averaged from three cardiac cycles. All study patients were divided according to American Society of Echocardiography/European Association of Cardiovascular Imaging recommendations for the classification of LV diastolic dysfunction.21 Since all patients had normal LVEF, the following criteria were taken into evaluation: average E/e′, both septal and lateral e′ velocities, tricuspid regurgitation velocity and LA volume index.

These criteria split the patients into three subgroups showing LV diastolic function. In the indeterminate subgroup, if the difference in pulmonary venous flow atrial reversal duration to mitral inflow A wave duration was more than 30 ms, the data were used as a marker of DD and elevated LV filling pressure.22

Table 2 shows TTE derived LA function analysis. Total, passive and active emptying volumes and fractions were calculated from TTE data according to Blume et al23 with a proposed additional new index of conduit ratio where LV stroke volume is being divided by the difference between the maximum and the minimum LA volume. LA expansion index was calculated according to Thomas et al.24

Table 2

(A) Transthoracic echocardiogram (TTE) assessment of left atrial (LA) function; (B) CT coronary angiography (CTCA) derived measurements for left ventricle (LV) diastolic dysfunction (DD)

Statistical analysis

Continuous variables are expressed as mean±SD, and were compared using the t-test. Categorical variables are expressed as percentages. LV, LA volumes and DE, DEF by CTCA and TTE measurements were assessed using Pearson’s correlation. One-way analysis of variance (ANOVA) was used to determine differences in CTCA derived diastolic volume measurements and TTE derived diastolic function. The agreement between CTCA LA diastolic volume and TTE maximum, pre-A and minimum volume was calculated using Bland-Altman’s plots. Multiple regression analysis was used to determine the contribution of anthropometric and TTE parameters for DE and DEF. Sensitivity, specificity, positive and negative predictive values were calculated in standard manner. For all analyses, p values <0.05 were considered statistically significant. The statistical analysis was performed using commercially available software (JMP V.15; SAS Institute).

Interobserver and intraobserver agreement was assessed in 28 randomly selected patients.

Results

Table 3 presents TTE data.

Table 3

Transthoracic echocardiogram (TTE) data

CTCA derived volumes of both the LV and the LA were significantly larger compared with those obtained from TTE. CTCA derived LV volume was on average 37%±20% bigger than that measured from TTE (40±23 mL for absolute values and 21±11 mL/m2 for indexed volumes). There was a good correlation between those measurements (R2=0.58; p<0.001). This was consistent for both absolute measurements (128±35 mL vs 95±28 mL; p<0.001) and for indexed measurements (67±14 mL/m2 vs 49±11 mL/m2.; p<0.01).

CTCA derived LA volumes were larger than the TTE maximum LA volumes for both absolute measurements (81±21 mL vs 72±25 mL; p<0.01) and for indexed measurements (43±9 mL/m2 vs 38±12 mL/m2 ; p<0.01). CTCA derived LA diastolic volume correlated well with all TTE derived diastolic LA volumes: for maximum LA volume, R2=0.58; p<0.001, for LA pre-A volume, R2=0.39; p<0.001, and for LA minimal volume R2=0.26; p<0.001 (figure 3A–C). The smallest differences in volume measurements were found between CTCA LA volume and TTE maximum LA volume (figure 3D–F). The mean difference between CTCA LA volume and TTE maximum LA volume was 9±16 mL and 5±9 mL/m2, for absolute and indexed measurements, respectively. The average percentage of difference was 11%±21%.

Figure 3

(A) Linear correlation between CTCA diastolic LA volume and TTE maximum LA volume. (B) Linear correlation between CTCA diastolic LA volume and TTE pre-A LA volume. (C) Linear correlation between CTCA diastolic LA volume and TTE minimum LA volume. (D) Bland and Altman plot. Differences between CTCA diastolic LA volume and TTE maximum LA volume. (E). Bland and Altman plot. Differences between CTCA diastolic LA volume and TTE pre-A LA volume. (F) Bland and Altman plot. Differences between CTCA diastolic LA volume and TTE minimum LA volume. CTCA, CT coronary angiography; LA, left atrium; TTE, transthoracic echocardiogram.

TTE LA function analysis and CT derived DE and DEF are presented in table 4.

Table 4

Transthoracic echocardiogram (TTE) left atrial (LA) function analysis and CT coronary angiography (CTCA) derived indices

The DE and DEF correlated with the following TTE LA function indices: (i) for LA pump (booster) function: LA active emptying volume, (ii) for LA conduit function: LA passive emptying fraction, for conduit: ratio and (iii) for LA reservoir: total emptying fraction and LA expansion index. The best but weak correlation was between DEF and LA active emptying volume (R2=0.19, p<0.0001).

Table 5 summarises the comparison between CTCA derived data in all three subgroups of patients divided according to their diastolic function result: normal (n=42, 58%), LVDD (n=20, 28%) and indeterminate (n=10, 14%). Analysing CTCA data, patients with normal LV diastolic function had bigger: LV diastolic volumes (absolute and indexed for body surface area), LA volume indices (adjusted for body surfaced area but not absolute). Additionally, DE and DEF values were significantly higher in patients with normal LV diastolic function as opposed to those with either abnormal or indeterminate diastolic function (figure 4A–D).

Figure 4

(A) Comparison between CT coronary angiography (CTCA) derived diastolic expansion (DE) and transthoracic echocardiography (TTE) assessed LV diastolic dysfunction (DD). (B) Comparison between CTCA derived DE fraction (DEF) and TTE assessed LV DD. (C) Comparison between CTCA derived diastolic LA volume and TTE assessed LV DD. (D) Comparison between CTCA derived diastolic LA volume index and TTE assessed LV DD. Red dots indicate the patients with documented elevated LV filling pressure by cardiac catheterisation. DE is calculated as a ratio (LV volume÷LA volume) measured during diastasis and acquired by CTCA. DD is assessed by TTE according to American Society of Echocardiography/European Association of Cardiovascular Imagingrecommendations. DEF is calculated as a {[(LV volume–LA volume)÷LV volume]×100} measured during diastasis and acquired by CTCA. LA, left atrial; LV, left ventricle.

Table 5

Comparison between normal and elevated and/or indeterminate left ventricle (LV) filling pressure and CT coronary angiography (CTCA) derived diastolic indices

DE and DEF decreased independently according to LVDD and increasing age (table 6). The difference in heart rate, and the time delay between TTE and CTCA measurements were not contributing to DE or DEF.

Table 6

The contribution of parameters on diastolic expansion (DE) and diastolic expansion fraction (DEF) indices by multiple regression analysis

Among all CTCA diastolic volumes measurements only DE allowed to differentiate normal from abnormal LV diastolic function. The DE value above 1.65 has 85% specificity (95% CI 0.69 to 1.01) and 88% positive predictive value (95% CI 0.75 to 1.01) for the diagnosis of normal LV diastolic function. DE value below 1.40 has 88% specificity (95% CI 0.78 to 0.98) and 62% positive predictive value (95% CI 0.35 to 0.88) to diagnose abnormal LV diastolic function (table 7A).

Table 7

Accuracy of CT coronary angiography derived diastolic expansion to differentiate presence of normal vs (A) abnormal, (B) indeterminate or (C) either abnormal or indeterminate left ventricle diastolic function

DE markers above 1.65and below 1.40 were also noted to differentiate normal from indeterminate LV diastolic function (table 7B) and normal from both indeterminate and abnormal LV diastolic function (table 7B,C).

As previously discussed, the presence of elevated LV diastolic pressure was confirmed in nine patients based on invasive CA. The measured range was 16–49 mm Hg, mean 25±13 mm Hg. This group of patients had lower DE and DEF (1.37±0.18 vs 1.79±0.45 and 26±10 vs 41±13, p<0.01, respectively). There were no significant changes in either LA volume or LA volume index (81±21 mL vs 79±22 mL and 45±11 mL/m2 vs 41±9 mL/m2, p=NS, respectively).

Interobserver and intraobserver agreement

The agreement in CT LA volume measurements was assessed in 28 randomly selected patients with a mean LA volume of 88±26 mL. The mean difference between two observers was −3.6±2 SD 7.6 mL (95% limits of agreement). This represents on average 4%±7% of the LA volume differences between two independent observers. The mean difference between manually traced and automated LA volume was 0±2 SD 3.8 mL. This represents on average 0%±5% of the LA volume difference between the manual and automated measurements.

Discussion

This study provides several observations on LA and LV volume measurements obtained from prospectively triggered CTCA. It also provides a new observation illustrating the potential role of CTCA in the assessment of LVDD. Since the word diastole, originally derived from Greek, means ‘dilatation or expansion’, DE and DEF were chosen as terms to represent new indices of interest measured in the study.

The main findings of this study are summarised as follows:

  1. In agreement with others, CTCA derived volumes of both the LV and the LA correlated well with TTE measurements but were larger compared with those obtained from TTE.7–14 CTCA derived LV volume measured in diastasis was on average 37%±20% bigger than that measured from TTE. CTCA derived LA diastolic volume correlated well with all TTE derived diastolic LA volumes, with the closest correlation being both maximum LA volume and LA pre-A volume. The average percentage of difference between CTCA- LA volume and TTE maximum LA volume was 11%±21%. The observed differences in measurements between TTE and CTCA reflect a difference in protocol of image acquisition. In prospectively triggered CTCA protocol, in order to reduce the amount of radiation, a selected phase of a cardiac cycle is acquired. Since CTCA is becoming almost a ‘bedside’ test in patients with chest pain assessment and intermediate pretest probability,1–4 we aimed to record the trend in differences in volume measurements between TTE and CTCA. We did not attempt to use the prediction model of LVEDV developed by Khatri et al14 who proposed a mathematic method of LV end-diastolic volume estimation from prospectively gated CTCA. As volume assessment was not our main aim we did not focus on this topic further. However, our results are similar to those by Khatri et al.

  2. CTCA derived DE and DEF correlated with LA active emptying volume, LA passive emptying fraction, conduit ratio and both total emptying fraction and LA expansion index.

  3. Patients with normal LV diastolic function, as opposed to either indeterminate or abnormal LV diastolic function, showed bigger values in the following parameters: LV diastolic volumes, LA volume indices, DE and DEF. However, only the DE allowed to differentiate normal from either abnormal or indeterminate LV diastolic functions with good accuracy. The DE value above 1.65 was indicative of a normal LV diastolic function, while a value below 1.4 was indicative of either abnormal and/or indeterminate LV diastolic function. It appears that DE holds a promise to be a reliable parameter that may be easily calculated from information available from conventional diastolic CTCA scans.

The question is: why should we be interested in measuring LVDD from CTCA data since both TTE and cardiac MRI25–28 are well recognised and widely available techniques that already do this well? Achenbach et al29 posed such a question in their editor’s page for the Journal of the American College of Cardiology Cardiovascular Imaging entitled ‘Climbing Mount Everest “Because It’s There”’ in response to Boogers et al paper on feasibility of LVDD assessment with cardiac CT.15 It was then agreed that additional information on DD may add to the growing list on noncoronary applications of cardiac CT. Such incremental prognostic value indices may potentially translate into more relevant information and as a result improve the management and the prognosis.

Thus far, LVDD was assessed in protocols where retrospective gating was used resulting in the acquisition of the entire cardiac cycle data and higher radiation dose.12–14 However, our study is the first to look at the feasibility of CTCA with prospective ECG triggering in the assessment of LVDD.

LA to LV ratio was measured in 2007 by Germans et al, in a group of healthy volunteers using cardiac MRI.30 Their reported ratios of LA to LV volumes were increasing with age. A similar concept was applied by Takeuchi et al,31 where LV to LA ratio (the reversed ratio as compared with Germans et al) was measured using three-dimensional echocardiography and once again showing a similar change with age.31 The authors suggested that this observation might be useful to elucidate abnormal LV to LA coupling in patients with heart failure.30 31 In the current study, both LVDD and increasing age lowered DE, but the contribution of those factors was independent. As DE can be obtained easily and with excellent reproducibility during a routine prospectively gated CTCA, it’s prognostic value may become useful in risk stratification by identifying characteristics that can predict future adverse events, and to guide primary or secondary prevention.

Conclusions

This new study establishes the potential clinical value of CTCA LV and LA volume measurements, which were taken during diastasis in the assessment of LVDD. Both DE and DEF can be obtained easily and with excellent reproducibility during a routine prospectively triggered CTCA study. The DE value above 1.65 was indicative of normal LV diastolic function, while a value below 1.4 was indicative of either abnormal and/or intermediate LV diastolic function (figure 5). This added information may assist in the early detection of subclinical diseases, and may also refine risk stratification in patients undergoing CTCA. A larger group of patients will need to be studied to further strengthen the reliability of our results on the role of DE in the assessment of LVDD.

Figure 5

Schematic diagram illustrating the principle of diastolic expansion (DE) index derived from CT coronary angiography. LA, left atrial; LV, left ventricle.

Limitations

This is a retrospective designed study with a relatively long time difference between CTCA and TTE. Despite this limitation, all our patients were clinically stable with preserved LVEF ≥50%, and there were no changes in medications between these two tests. Therefore, the potential effect of pre-load and after-load was minimal.

Additionally, none of our patients were on loop diuretics. In order to minimise other factors on the LV diastolic function, patients with atrial fibrillation, permanent pacemakers, and significant valvular pathology were excluded. A small group of patients needed to be excluded due to higher heart rate during image acquisition, which resulted in a systolic scan. Only a small group of patients underwent invasive cardiac catheterisation and/or subsequent coronary artery revascularisation. Although the results from this subgroup were in concordance with the main results, more invasive data would add further value to the manuscript.

Acknowledgments

We would like to thank Professor Robert Ware from the Griffith University, Queensland for his critical comments and statistical advice.

References

Footnotes

  • Contributors AL, the corresponding author, is responsible for the conception and design of the study, along with the interpretation of the data. PP is responsible for the collection and analysis of the data, and the interpretation of the data. JS and HH are responsible for the analysis of CT data. All authors took part in drafting the manuscript and AL and PP took part in revising the manuscript critically for important intellectual content.

  • Funding This project was supported by Wesley Medical Research Clinical Research Grant #2020-23.

  • Disclaimer All authors report that they have no relationship with the industry to be disclosed.

  • Competing interests None declared.

  • Patient consent for publication Not required.

  • Ethics approval The Institutional Ethical Committee approved the retrospective use of clinical data and informed written consent was obtained from all patients.

  • Provenance and peer review Not commissioned; externally peer reviewed.

  • Data availability statement Data are available upon reasonable request.